FBG-Scan 80X

The FBG-Scan 80X is a dynamic, precise measurement device for Fiber Bragg Grating (FBG) sensors based on spectrometer technology.

对不起,此内容只适用于En。 For the sake of viewer convenience, the content is shown below in the alternative language. You may click the link to switch the active language.

The FBG-Scan 80X is a dynamic, precise measurement device for Fiber Bragg Grating (FBG) sensors based on spectrometer technology. The system offers a cost effective solution and is offered as a 1, 4 or 8 channel system. All sensors can be monitored with a sampling rate of 2kHz, 500Hz or 250Hz respectively. The system has a wavelength stability of 1pm at full measurement speed and has an absolute End Of Life wavelength accuracy of 40pm. The sampling is done using the internal clock or can be controlled by an external trigger signal to synchronize the measurements with other devices. The system is supplied with the “ILLumiSense” software, which is used to visualize and process the FBG wavelengths on a PC and convert these data into engineered data such as temperature and strain values.

 

Features

∙ 4 or 8 individual optical channels
∙ Up to 40 sensors per optical channel
∙ Wavelength stability of 1pm (1) @ full sampling rate
∙ No need for time of flight corrections to maintain wavelength accuracy
∙ Depolarized light source to reduce birefringence induced noise effects
∙ High dynamic range ≥ 30dB
∙ External triggering possible
∙ Simultaneous detection of sensors belonging to the same optical channel

Specifications

Parameter FBG-Scan 800 804 808

 

Optical
Number of channels 1 4 8
Wavelength range 1510 nm – 1590 nm
Wavelength precision (1δ) @ full measurement speed 1 pm
Wavelength linearity 10 pm
Absolute wavelength accuracy1

 

40 pm
Minimum wavelength spacing 0,8 nm
Dynamic range >30 dB (user selectable control)
Sampling rate – all channels active 2 kHz 500 Hz 250 Hz
Sampling rate – 1 channel active 2 kHz
5 kHz (visualization disabled)
Degree of polarization light source ≤ 5%
Optical connector LC/APC
Laser class (IEC 60825-1) 1
Electrical
Communication USB
External trigger ≤ 5 V DC; via SMA connector
Power supply 9-15 V DC
Power consumption <10W
Environmental
Operating temperature 0 to 45°C
Operating humidity 0% to 80%RH, non-condensing
Mechanical
Weight 2,4 kg
Dimensions (WxDxH) 250 x 180 x 60 mm

Measurement device FBG-Scan 80X

下载技术资料

请填写您的信息以下载更多关于我们产品的信息

CAPTCHA image

* 这些字段是必需的。

我们如何使用您的信息

我们承诺尊重您的隐私,保护您的个人信息。在我们的隐私申明中,您可以了解我们如何处理您的数据,以及我们如何使用这些数据为您提供更好的服务

通过提交本表格,您同意按照我们的隐私声明使用您的数据

更多 测量设备

ILLumiSense Software v2.3.x

This software has been developed to perform real time measurements using the FBG-Scan interrogator series of FBGS. It supports both the 80X as well as the 90X series and also supports the EP-versions of those systems (Embedded Processing).

密码保护:InfinityScan

无法提供摘要。这是一篇受保护的文章。

FBG-Scan 90X解调设备

FBG-Scan 90X是一种动态,精确的测量设备,用于基于光谱仪技术的光纤布拉格光栅(FBG)传感器。该系统提供了具有成本效益的解决方案,并以4或8通道系统的形式提供。

FBG-Scan 915-EP解调设备

FBG- Scan 915-EP是FBGS基于光谱仪的FBG解调技术的旗舰产品,结合了15个光学通道和FBG- Scan 90X系列的顶级性能。 这款产品专为工业环境所开发,在开启所有通道并进行全速测量的条件下,能够实现无与伦比的0.3pm测量精度。

询问器FBG-Scan X0X-EP

FBG-Scan X0X-EP系列询问单元是指FBG-Scan 804、808、904或908光学引擎与19英寸机箱中的嵌入式处理(EP)平台相结合

登记并获取简讯

联系我们

    Code:  

     

    我们如何使用您的信息

    我们承诺尊重您的隐私,保护您的个人信息。在我们的隐私申明中,您可以了解我们如何处理您的数据,以及我们如何使用这些数据为您提供更好的服务

    通过提交本表格,您同意按照我们的隐私声明使用您的数据

    Germany

    FBGS Technologies GmbH
    Franz Loewen Straße 3
    D-07745 Jena

    Belgium

    FBGS International NV
    Bell Telephonelaan 2H
    B-2440 Geel

    China

    Suzhou X2 Electronic Technology Co Ltd
    Room No. 2003, Building 38, No. 60 Weixin Road, Suzhou Industrial Park
    215122 Suzhou, Jiangsu China

    USA

    Montreal